Showing posts with label copper winding wire. Show all posts
Showing posts with label copper winding wire. Show all posts

2015/10/09

Polyurethane Enameled Round Copper Wire


Material: Insulating Varnish composed of polyurethane resin over round copper conductor.

Features: Most widely used enameled wire. Solderable at 380C. Easily colored in a variety of colors. Excellent dielectric characteristics at high frequencies.


Applications: Relays, Small motors, Small transformers, Magnetic heads, Coils for telecommunication equipment.


2015/09/24

kapton magnet wire


Kapton magnet wire is premium copper or aluminum conductor, evenly wrapped with polyimide film or polyimide, fluorine 4.6 composite film. Fluorine 4.6 can be melt and make a whole with the film and conductor after heated.



Kapton magnet wire has strong voltage resistance, thin thickness and thermal class up to 220℃. The product is widely applied in electric machines、reactors、electric welding machines and similar electrical instruments. The electrical bare copper or aluminum wire with extrusion process is the ideal material for polyimide film wrapped copper or aluminum wire.

2015/09/17

Enamelled Copper Wire Specifications


Zhengzhou LP Industry Co., Ltd is a China professional manufacture of magnet wire, our company can supply for different specifications and different diameter of enamelled copper wire.




Specifications:

Class 130 Polyester Enamelled Copper Wire

Class 155 Modified Polyester Enamelled Copper Wire

Class 180 Polyesterimide Enamelled Copper Wire

Class 200 Polyesterimide &Polyesterimide Enamelled Copper Wire

Class 220 Polyesterimide &Polyesterimide Enamelled Copper Wire

Kapton Copper Wire

Ultra Fine Rectangular Enamelled Copper Wire

Ultra Fine Self-bonding Ultra Fine Rectangular Enamelled Copper Wire

2014/11/03

Comparison of copper and aluminum winding wire


1.A calculation for aluminium and copper wires.
Copper has lower resistance per unit volume, ie, a 1 cm diameter copper wire has less resistance than a 1 cm aluminum wire.

BUT, aluminum is much lighter than Cu for the same diameter. If you used an aluminum wire that weighs the same as the 1 cm diameter copper wire, it would have LOWER resistance. And that is

why aluminum is used in power transmission, and also in aircraft, where weight is important.
To do this you calculate density resistivity which is (resistivity x density). Here is a partial table:
Al 28.2e-9 Ω-m * 2700 kg/m³ = 76e-6 Ω-kg/m²
Cu 17.2e-9 Ω-m * 8960 kg/m³ = 154e-6 Ω-kg/m²
Ag 15.9e-9 Ω-m * 10500 kg/m³ = 167e-6 Ω-kg/m²
Au 22.14e-9 Ω-m * 19300 kg/m³ = 427e-6 Ω-kg/m²
Zn 68e-9 Ω-m * 7130 kg/m³ = 485-6 Ω-kg/m²
Fe 100e-9 Ω-m * 7870 kg/m³ = 787e-6 Ω-kg/m²

Note that Al is half that of Cu.

2.How to replace the aluminum winding wire to copper wire in one transformer?
Since aluminum wire is slightly more than copper you'll need to account for the change in voltage drop.
If you replace just one half of the transformer with copper wire you'll need a resistor in series (series resistors add to the resistance).
If you replace both sides with copper wiring then you will not need a resistor to account for the changes.
Or you can purchase a new transformer. And you should expect that with an equivalent rating,
a transformer with copper winding will cost more than a transformer with aluminum winding.